If you have an existing heating system a small underfloor heating area can be added. Suitable places include bathrooms, extensions and conservatories
Normally existing boilers have sufficient capacity to cope with the increased load.
We sell two basic types of floor heating system which are plumbed into the existing central heating:
This underfloor heating system will come on with the rest of the central heating. It cannot 'call' the boiler independently.
The water in the underfloor pipe is temperature controlled by use of a 'return temperature limiter' valve.
This is the least expensive option but it is not suitable for under a wooden floor and the underfloor pipes must be set into screed.
The kit works off a two pipe central heating circuit and is not suitable for whole house operation
This system can call the boiler independently of the main heating so that the heat can remain on in an extension or conservatory when the rest of the house is shut off.
It is controlled by a timer and a thermostat in the room and the water temperature in the underfloor pipes is controlled by a mixer valve. There is also a separate pump which is activated by the timer thermostat.
Here the main flow and return pipes must be taken back to the boiler as this system is not suitable for plumbing into the local central heating pipes.
This system is so controllable that it is suitable for any type of floor.
The ground floor must be well insulated and 60mm of high value polyurethane floor insulation is recommended. If the floor is to be screeded then a further 75mm of screed is required. The pipes are laid in the screed.
The heating pipes can also be laid below a timber floor. Insulation is required between the joists.
Follow the diagram supplied with your kit. The pipe is marked in metres to aid cutting to the right length.
Simply lay the barrier pipe onto the floor insulation using clips or onto thin weld mesh over the floor insulation and tie into place. Bring all the tails to the chosen manifold position.
After pressure testing screed is laid over the pipes to depth of 65-75mm.
Allow new floor screed to dry out before heating the floor.
Kit 1 a
Return temperature limiter with sensor and isolation valves
Also a roll of underfloor pipe
Kit 1 b / c
Manifold with two return temperature limiters. (This arrangement can vary depending on your layout and may include manifolds with more 'ways')
Also rolls of underfloor pipe
Design of your system showing pipe layout
Underfloor Heating and Flooring Guides
Return
temperature limiter valve(s) c/w sensor(s)
Dow
Corning Underfloor Pex pipe 16mm. Length
to suit layout
Flow
and return manifolds (or valve connections as required kit 1a)
All
BSP connections and underfloor pipe connections
Two
22mm ball isolation valves and 22mm tees
Manifold
brackets
|
Room
Size (Approx, depending on
insulation) a)
16 sqm insulated room or 12 sqm Conservatory b)
40 sqm insulated rooms or 30 sqm Conservatory |
Cost £289.00 £418.43 |
Cost
including VAT and delivery £363.08 £515.16 |
Mixer valve,
Pump,
Manifold
with brackets.
(Manifolds may have more or fewer ‘ways’ depending on
layout)
Separate room temperature control using electric actuators
Twin channel timer
Roomstat(s) with night set back
Wiring centre with 2 control relays
Design
- showing pipe layout and connections to boiler
Underfloor
heating and flooring guides
Installation
instructions
Dow
Corning Pex barrier pipe 16mm. Length
to suit layout
Flow
and return manifolds: Manifold 1/1/4", ¾” outlets c/w air vent and drain, brackets, and underfloor pipe connections
High
flow Mixer valve,
Pump
and pump valves
Twin
channel timer for underfloor zone and existing heating zone
Twin
relay wiring centre
Roomstats
with night set back
Electric
heads for manifold
Zone
valve 22mm optional
|
Room Size (approx depending on insulation) a)
Up to 50 sqm insulated rooms or 30 sqm Conservatory b)
Up to 80 sqm insulated rooms or 50 sqm Conservatory |
Cost £689.57 £848.61 |
Cost including VAT and delivery £857.24 £1044.12 |
Parts that must be supplied by the client:
Insulation under pipes
Weld
mesh - 10 gauge 4" from a steel stockholder (optional)
Tie
downs for pipe
- plastic coated wire
Compression connections to existing system
For
kit 2 client needs to provide 22mm pipe from site of manifold back to the
boiler.
Plans
to include
Plan
of rooms to be heated with underfloor heating
Room
heights
Whether
there is a room above or roof insulation
Insulation
or construction of all walls
Joist
spacing
Window
sizes and type of glazing